Modbus Gateway supports the four most commonly used communication standards,
RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided
with Modbus Gateway can quickly select the hardware interface , and easily
switch to the existing communication infrastructure. Industrial EMC protection
and wide temperature operation capability make MB5202 ready for every mission.
Switching between Modbus Protocols
Modbus Gateway supports the standard Modbus protocol and is capable of
converting any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus
ASCII for all supported hardware interfaces.
Modbus
ID Routing
Modbus Gateway supports various types of hardware communication interfaces,
Modbus protocol conversion, and Modbus ID routing. Therefore the Modbus Gateway
can integrate your existing and complex Modbus hardware configuration into a
simple network that can be easily managed.
INTRODUCTION
NETWORK INTERFACE
Ethernet Port
1x 10/100BASE-T(X) RJ-45 or 1x100BASE-FX SFP Slot
Compliance
IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-T(X) and 100BASE-FX
Atop Management Utility, Web UI, Telnet, Serial Console
VirtualCOM
Windows/Linux redirection software
Modbus
TCP/RTU/ASCII
TCP Client
Single destination or VirtualCOM
TCP Server
4 Connections; VirtualCOM or reverse Telnet
UDP
Up to 4 Ranges IP
POWER
Input Voltage
3-Pin 5.08mm Terminal Block: 9-30VDC; DC Lockable Jack 5VDC
Isolation
3kV (-Sis versions only)
Power Redundancy
Yes
Power Consumption
<3W
Connector
3-Pin 5.08mm Lockable Terminal Block and DC Jack for redundancy
Reverse Polarity Protection
Yes
PHYSICAL CHARACTERISTICS
Dimension (W x H x D)
75 mm x 85 mm x 28 mm (without wall-mount part) SE5202-TB/SE5202-Sis: 74.5 x 108.2 x27.5mm (with wall-mount part) SE5202-DB: 80.3 x 108.2 x27.5mm (with wall-mount part and DB9 connector) SE5202-SFP-TB: 76.6 x 108.2 x 27.5mm (with wall-mount and SFP) SE5202-SFP-DB: 81.4 x 108.2 x 27.5mm (with wall-mount SFP and DB9)